@asgothian sagte in Sonoff SWV erhält keine Daten:
Sorry - wollte ich gerade nachreichen
Welche Firmware hast du auf dem SWV ?
1.0.4
bbf5f049-bc33-442a-8104-cf44871c7814-image.png
Welche Adapter version hast du ?
2.0.5
15dd6190-cc11-4cba-a2c2-a6e31dcca8a1-image.png
Hast du versucht das SWV von der Kachel aus neu zu konfigurieren ?
Hatte ich gestern schon mehrfach versucht. Heute dummerweise nicht mehr.
Sieht jetzt auf jeden Fall besser aus.
Scheint ein wenig zickig zu sein das Gerät 😉
2025-07-22 12:44:57.214 - warn: zigbee.0 (769) ELEVATED:I01 (8cfe) Zigbee Event of Type readResponse from device 0x44e2f8fffe0528e7, incoming event: {"type":"readResponse","data":{"20492":0,"lackWaterCloseValveTimeout":30},"linkquality":91,"groupID":0,"cluster":"customClusterEwelink","meta":{"zclTransactionSequenceNumber":90,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
2025-07-22 12:44:57.216 - warn: zigbee.0 (769) ELEVATED:I01 (8cfe) message received '{"linkquality":91}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:44:57.216 - warn: zigbee.0 (769) ELEVATED:I02 (8cfe) value generated '91' from device 44e2f8fffe0528e7 for 'Link quality'
2025-07-22 12:44:57.218 - warn: zigbee.0 (769) ELEVATED:I01 (8cfe) message received '{"current_device_status":"normal_state"}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:44:57.218 - warn: zigbee.0 (769) ELEVATED:I02 (8cfe) value generated '"normal_state"' from device 44e2f8fffe0528e7 for 'The water valve is in normal state, water shortage or water leakage'
2025-07-22 12:44:57.262 - warn: zigbee.0 (769) ELEVATED:I01 (8cfe) message received '{"auto_close_when_water_shortage":"ENABLE"}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:44:57.262 - warn: zigbee.0 (769) ELEVATED:I02 (8cfe) value generated 'true' from device 44e2f8fffe0528e7 for 'Automatically shut down the water valve after the water shortage exceeds 30 minutes. Requires firmware version 1.0.4 or later!'
2025-07-22 12:45:00.701 - warn: zigbee.0 (769) ELEVATED:I01 (9a9d) Zigbee Event of Type readResponse from device 0x44e2f8fffe0528e7, incoming event: {"type":"readResponse","data":{"batteryPercentageRemaining":200},"linkquality":94,"groupID":0,"cluster":"genPowerCfg","meta":{"zclTransactionSequenceNumber":92,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
2025-07-22 12:45:00.702 - warn: zigbee.0 (769) ELEVATED:I01 (9a9d) message received '{"linkquality":94}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:45:00.702 - warn: zigbee.0 (769) ELEVATED:I02 (9a9d) value generated '94' from device 44e2f8fffe0528e7 for 'Link quality'
2025-07-22 12:45:00.704 - warn: zigbee.0 (769) ELEVATED:I01 (9a9d) message received '{"battery":100}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:45:00.704 - warn: zigbee.0 (769) ELEVATED:I02 (9a9d) value generated '100' from device 44e2f8fffe0528e7 for 'Battery percent'
2025-07-22 12:45:04.184 - warn: zigbee.0 (769) ELEVATED:I01 (a838) Zigbee Event of Type readResponse from device 0x44e2f8fffe0528e7, incoming event: {"type":"readResponse","data":{"onOff":0},"linkquality":91,"groupID":0,"cluster":"genOnOff","meta":{"zclTransactionSequenceNumber":94,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
2025-07-22 12:45:04.186 - warn: zigbee.0 (769) ELEVATED:I01 (a838) message received '{"linkquality":91}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:45:04.186 - warn: zigbee.0 (769) ELEVATED:I02 (a838) value generated '91' from device 44e2f8fffe0528e7 for 'Link quality'
2025-07-22 12:45:04.188 - warn: zigbee.0 (769) ELEVATED:I01 (a838) message received '{"state":"OFF"}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:45:04.188 - warn: zigbee.0 (769) ELEVATED:I02 (a838) value generated 'false' from device 44e2f8fffe0528e7 for 'On/off state of the switch'
2025-07-22 12:45:05.179 - warn: zigbee.0 (769) ELEVATED:I01 (ac1b) Zigbee Event of Type readResponse from device 0x44e2f8fffe0528e7, incoming event: {"type":"readResponse","data":{"20492":0},"linkquality":91,"groupID":0,"cluster":"customClusterEwelink","meta":{"zclTransactionSequenceNumber":95,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
2025-07-22 12:45:05.189 - warn: zigbee.0 (769) ELEVATED:I01 (ac1b) message received '{"linkquality":91}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:45:05.189 - warn: zigbee.0 (769) ELEVATED:I02 (ac1b) value generated '91' from device 44e2f8fffe0528e7 for 'Link quality'
2025-07-22 12:45:05.191 - warn: zigbee.0 (769) ELEVATED:I01 (ac1b) message received '{"current_device_status":"normal_state"}' from device 44e2f8fffe0528e7 type 'SWV'
2025-07-22 12:45:05.191 - warn: zigbee.0 (769) ELEVATED:I02 (ac1b) value generated '"normal_state"' from device 44e2f8fffe0528e7 for 'The water valve is in normal state, water shortage or water leakage'